Application:
Clean Water from Coil Cleaning for Sanitary Sewer Discharge
Description: Contaminated water from the coil system flows into a holding tank in basement with a dual pump and float control arrangement from pump alternation and overflow. The water is then pumped to our Model MV for free oil and solids separation and discharged to our holding tank. The holding tank discharge is a dual pump and control arrangement (max. 100 GPM @ 70 psi ? 10 HP) transferring the water through our dual filter canister set-up to a DAF System. The DAF discharge water passes to the sanitary sewer or through our treated carbon Media Canister, if necessary, then to a sanitary sewer.
Customer:
Equipment & Truck Rental Company
Business Type:
Heavy Equipment Rental
Application:
Processing wash down water to be discharged to sanitary sewer.
Description: The sump system is comprised of a drive-in slanted sump for easy disposal of solids. The water then flows into two successive sumps where from the last sump it is pumped to the Model MV for processing and discharge to the sanitary sewer.
Comments: This system was installed in a new building and functions successfully in this wash down application with low maintenance and low operating cost.